Medical-grade sterilization
Every reusable metal instrument goes through six stages before it is used again: pre-sterilization cleaning, drying, individual packaging, Class B steam sterilization, protected storage, and documented cycle checks. Our process combines disinfectant soaking, brush and ultrasonic cleaning, an autoclave at 134°C (273°F), and chemical and biological monitoring. Your technician opens the sealed pouch in front of you when your service begins.
You should never have to guess if a tool is clean. We log every cycle, and we open your sealed pouch directly in front of you.
Pre-Sterilization Cleaning
Immediately after use, reusable metal instruments are immersed in a disinfectant solution with a cleaning action. The soaking time follows the product instructions, typically 10–15 minutes; the required contact time always takes priority. Our team replaces the solution according to its instructions and our cleaning schedule. Instruments are rinsed under running water and cleaned with a brush and an ultrasonic bath to remove residue from hinges, joints, and e-file bits before sterilization.
Thorough Drying
After cleaning and rinsing, instruments are thoroughly dried with disposable lint-free wipes or air. Every instrument must be completely dry before it is placed in a sterilization pouch. We check hinges, joints, and other areas where water can collect, because residual moisture can compromise the packaging and contribute to corrosion.
Individual Sealed Packaging
We package one instrument per pouch, using steam-compatible sterilization pouches, such as kraft or self-sealing pouches, with chemical indicators. Each pouch is labeled with the processing date and the technician’s signature. The packaging is sealed according to the pouch manufacturer’s instructions and checked for tears, punctures, or an incomplete seal.
Autoclave Sterilization
Sealed instruments are processed in a Class B autoclave using saturated steam at 134°C (273°F) and approximately 2.1 bar of pressure above atmospheric pressure. A complete cycle typically takes 30–45 minutes, including preparation, sterilization, and drying; the exact program and sterilization exposure time follow the autoclave manufacturer’s instructions for the packaged load. We check both external and internal chemical indicators and perform regular biological spore testing to monitor the sterilization process. An indicator’s color change shows exposure to specified processing conditions; it does not, by itself, prove sterility. Instruments are not released for use if cycle readings or chemical indicators show inadequate processing.
Protected Storage
After the cycle is complete and the pouches are dry, packaged instruments are stored in a dry, closed cabinet, protected from dust and moisture. Pouches stay unopened until the instrument is needed for your service. Our storage limit is up to 30 days, provided the pouch remains intact and its manufacturer’s instructions allow that period. Before use, your technician checks the date, seal, dryness, and package integrity, then opens the pouch in front of you. Wet, torn, opened, or otherwise compromised pouches require reprocessing.
Sterilization Records
Every autoclave cycle is entered in our sterilization logbook. The record includes the processing date, the technician’s name, the list of instruments, the autoclave cycle number, and the indicator results. Cycle time, temperature, and pressure are recorded alongside the monitoring checks, with biological test results linked to the relevant test cycle. We retain the logbook for at least one year so each processed batch can be traced to its cycle and operator.
Single-Use Items
Porous supplies cannot withstand an autoclave, which means they must never be used twice. Nail files, buffing blocks, orange wood sticks, lint-free wipes, and technician gloves are unpacked fresh for your service and go straight into the trash when we finish.